DESPAIR-LAB

BREATH CONTROL SYSTEM 1.0

USER MANUAL

ENGINEERED FOR CONTROL

1. PRODUCT OVERVIEW

The DESPAIR-LAB BREATH CONTROL SYSTEM 1.0 is a programmable control system featuring a touchscreen interface, dual A/B valve control, configurable timing, cycle management, remote control, external trigger input, and optional scent-system integration.

The system provides four primary operating modes:

  • LOOP MODE
  • RANDOM MODE
  • SCENT MODE
  • TRIGGER MODE

The available controls and parameters vary according to the selected operating mode.

IMPORTANT

BREATH CONTROL SYSTEM 1.0 is a control device capable of controlling airflow-related equipment. The available timing parameters describe the operating range of the device and are not recommendations for any particular duration of use.

2. PACKAGE CONTENTS

The standard package includes:

2.1 Main Unit

BREATH CONTROL SYSTEM 1.0

The main control unit provides the touchscreen interface, A/B valve control, operating-mode management, and system settings.

2.2 Storage Case

A dedicated storage case is included for the main unit and accessories.

2.3 Remote Controller

The remote controller provides real-time access to the A/B valve controls.

2.4 Charger

The supplied charger is listed in the original package documentation as a 12.6V charger.

2.5 Trigger Connection Cable

A 2.5 mm trigger connection cable is included for use with the external passive-switch trigger interface.

3. MAIN UNIT

3.1 Touchscreen Display

The main unit is equipped with a 2.8-inch touchscreen.

The touchscreen is used to access:

  • Operating-mode selection
  • Mode parameters
  • A/B valve status
  • Timing information
  • Cycle information
  • System settings
  • Other operating controls

3.2 Power / Emergency Stop Switch

The front panel features a 16 mm illuminated switch.

The switch is used for:

  • Powering the main unit on
  • Emergency stopping the system

The switch illuminates red when the system is powered on.

3.3 Air-Tube Connections

The main unit uses standard 40 mm air-tube connections.

The product interface documentation identifies:

  • 40 mm standard male air-tube connector
  • 40 mm standard female air-tube connector

4. REAR INTERFACES

The rear panel provides three dedicated interfaces.

4.1 Charging Port

12.6V charging port

The main-unit interface diagram identifies the charging port as 12.6V.

NOTE

The package list identifies the supplied charger as 12V, while the main-unit interface diagram identifies the charging port as 12.6V. These specifications are retained according to the respective original product documents.

4.2 Scent Mode Signal Port

3.5 mm

The Scent Mode signal port is used to connect the main unit with a compatible scent-control unit.

4.3 Trigger Mode Signal Port

2.5 mm

The Trigger Mode signal port is designed for an external passive-switch signal.

WARNING

DO NOT INPUT VOLTAGE INTO THE TRIGGER MODE SIGNAL PORT.

The Trigger Mode interface is designed for a passive switch signal. Applying external voltage may damage the main-unit circuitry.

5. POWER ON

To power on the system:

  1. Press the silver switch beside the touchscreen.
  2. Release the switch.
  3. The switch illuminates red.
  4. The main unit performs a self-test.
  5. After approximately two seconds, the touchscreen illuminates.

The system is then ready for operation.

6. EMERGENCY STOP

The main power switch also functions as the emergency-stop control.

In an emergency:

Press the power / emergency-stop switch immediately.

According to the original system documentation, activating the emergency stop:

  • Immediately cuts power to the main unit.
  • Opens the air valve for ventilation.

WARNING

The emergency-stop switch must remain immediately accessible whenever the system is operating.

Never operate the system in a situation where immediate manual intervention is impossible.

7. HOME SCREEN

The Home Screen is the primary operating interface.

The available information and controls change according to the selected mode.

7.1 MODE SELECTION

Tap the mode-selection area to open the operating-mode menu.

The system provides:

  • LOOP MODE
  • RANDOM MODE
  • SCENT MODE
  • TRIGGER MODE

Select the required mode before configuring its parameters.

7.2 MODE SWITCH

After selecting an operating mode, use the mode switch to start the selected operation.

7.3 A/B VALVE STATUS

The Home Screen displays the current status of the A and B valves.

The displayed valve status changes in real time according to the current system state.

7.4 SETTINGS

Tap the Settings button to access the system settings and mode-parameter configuration pages.

8. HOME SCREEN INFORMATION

The Home Screen provides real-time operating information.

8.1 SET TIME / ELAPSED TIME

The interface displays both the configured time and elapsed time.

For example:

8:0

represents:

  • Set time: 8 seconds
  • Elapsed time: 0 seconds

8.2 REMAINING CYCLE COUNT

When a finite cycle count is configured, the remaining cycle count is displayed on the Home Screen.

When Infinite Loop is enabled, the remaining-cycle display is not shown.

8.3 TIME PROGRESS BAR

The progress bar changes according to the relationship between the configured time and the elapsed time.

8.4 A/B VALVE STATUS

The A/B valve status is updated in real time during operation.

8.5 CONTROL COUNT

The system records the total number of control events after power-on.

The control count is automatically cleared when the main unit is powered off.

9. TIMING PARAMETERS

The current version of BREATH CONTROL SYSTEM 1.0 uses the following timing limits:

ParameterCurrent SpecificationMinimum Ventilation Time6 secondsMaximum Closure Time60 seconds

These limits apply to the corresponding timing parameters used throughout the system.

IMPORTANT

The values above define the available device settings. They do not constitute a recommendation for a specific operating duration.

10. LOOP MODE

10.1 OVERVIEW

Loop Mode provides configurable timing and cycle control.

The available parameters include:

  • Valve Synchronization
  • Infinite Loop
  • Ventilation Time
  • Closure Time
  • Cycle Count
  • B Valve
  • Save

10.2 VALVE SYNCHRONIZATION

ON

When Valve Synchronization is enabled, the A and B valves operate according to synchronized control logic.

OFF

When Valve Synchronization is disabled, the B Valve configuration becomes available.

10.3 INFINITE LOOP

When Infinite Loop is enabled, the system continues operating until manually stopped.

When Infinite Loop is active:

  • Continuous operation is enabled.
  • Cycle Count is not used.
  • Manual stopping is required.

WARNING

Never enable continuous operation without maintaining immediate access to the stop and emergency-stop controls.

10.4 VENTILATION TIME

The current system supports a minimum ventilation-time setting of:

6 seconds

10.5 CLOSURE TIME

The current system supports a maximum closure-time setting of:

60 seconds

10.6 CYCLE COUNT

One complete ventilation-and-closure sequence is counted as one cycle.

When Infinite Loop is enabled, Cycle Count is inactive.

10.7 B VALVE

When Valve Synchronization is disabled, the B Valve can be configured according to the available system settings.

The original interface provides:

  • Normally Open
  • Normally Closed

10.8 SAVE

The Save function stores the configured parameters.

Saved parameters can be retained for subsequent use according to the system's parameter-storage function.

11. RANDOM MODE

11.1 OVERVIEW

Random Mode provides variable timing within configured time ranges.

The mode includes:

  • Valve Synchronization
  • Ventilation Time Range
  • Closure Time Range
  • B Valve
  • Continuous operation

11.2 VALVE SYNCHRONIZATION

When enabled, the A and B valves operate according to synchronized control logic.

When disabled, the B Valve setting becomes available.

11.3 VENTILATION TIME RANGE

The user can configure a ventilation-time range.

Minimum available ventilation time: 6 seconds

The system varies the operating time within the configured range.

11.4 CLOSURE TIME RANGE

The user can configure a closure-time range.

Maximum available closure time: 60 seconds

The system varies the operating time within the configured range.

11.5 B VALVE

When Valve Synchronization is disabled, the B Valve can be configured as:

  • Normally Open
  • Normally Closed

11.6 CONTINUOUS OPERATION

Random Mode supports continuous operation.

When continuous operation is enabled, the system must be manually stopped.

WARNING

Continuous operation should only be used when immediate manual intervention remains available.

12. SCENT MODE

12.1 OVERVIEW

Scent Mode allows BREATH CONTROL SYSTEM 1.0 to operate together with a compatible external scent-control unit.

The main unit communicates with the scent unit through the dedicated 3.5 mm Scent Mode signal port.

12.2 COMPATIBLE SCENT UNIT

Different production batches of the scent-control unit may use different internal circuits.

If a compatible scent unit does not operate correctly with the system, contact DESPAIR-LAB customer service for compatibility or upgrade assistance.

12.3 SCENT MODE PARAMETERS

Scent Mode provides the following parameters:

Infinite Loop

Enables continuous operation until manually stopped.

Ventilation Time

Controls the configured ventilation period.

Minimum: 6 seconds

Scent Delivery Time

Controls the operating duration of the connected scent-control unit.

Closure Time

Controls the configured closure period.

Maximum: 60 seconds

Cycle Count

A complete sequence consisting of ventilation, scent delivery, and closure is counted as one cycle.

12.4 SCENT UNIT CONNECTION

Connect the compatible scent-control unit to the dedicated:

3.5 mm Scent Mode signal port

The Scent Mode interface provides dedicated controls for:

  • Infinite Loop
  • Ventilation Time
  • Scent Delivery Time
  • Closure Time
  • Cycle Count
  • Save

13. REMOTE CONTROL MODE

13.1 ONE-KEY REMOTE ACTIVATION

Pressing any button on the remote controller immediately invokes Remote Control Mode.

The system then provides real-time A/B valve control through the remote controller.

13.2 A/B VALVE CONTROL

The remote controller provides dedicated controls for:

  • A Valve
  • B Valve

The corresponding valve can be controlled in real time.

13.3 TOUCHSCREEN MANUAL CONTROL

Remote Control Mode can also be accessed from the touchscreen.

After entering the Remote Control Mode page, select the corresponding A or B valve control.

13.4 SIMULTANEOUS CONTROL

According to the original system documentation, touchscreen manual control and remote-controller control do not conflict and may be used simultaneously.

IMPORTANT

Always maintain direct access to the emergency-stop control when using remote operation.

14. TRIGGER MODE

14.1 OVERVIEW

Trigger Mode provides an external trigger interface using a passive switch signal.

This function allows the system to be expanded with compatible external switching or sensing accessories.

14.2 TRIGGER INTERFACE

The dedicated Trigger Mode interface is:

2.5 mm signal port

14.3 PASSIVE SIGNAL ONLY

Trigger Mode is designed for a passive switching signal.

WARNING

DO NOT APPLY EXTERNAL VOLTAGE TO THE TRIGGER INTERFACE.

Applying voltage to the trigger input may damage the main-unit circuitry.

14.4 ELECTRICAL KNOWLEDGE

Trigger Mode requires an understanding of basic electrical connections.

Users without appropriate electrical knowledge should not attempt to configure or modify the trigger circuit.

15. EXTERNAL TRIGGER SOURCES

The original system documentation provides examples of possible external signal sources, including:

  • Sensors
  • Limit switches
  • Photoresistors
  • Microphone capsules
  • Distance-measuring modules
  • Liquid-level sensing arrangements
  • External remote switches

These examples describe possible signal sources and do not constitute a guarantee of compatibility with every third-party device.

16. TRIGGER CONNECTION CABLE

The supplied trigger connection cable uses a:

2.5 mm connector

A compatible two-core connection can be used with an appropriate passive trigger accessory.

If a compatible 2.5 mm two-core female connector is already available, the original documentation indicates that direct connection can be used without stripping the cable.

For custom electrical connections, users must ensure that the connected equipment provides an appropriate passive switching signal.

WARNING

Never connect an external voltage source to the Trigger Mode signal input.

17. GENERAL SETTINGS

The Settings interface provides access to:

  • Loop Mode parameters
  • Random Mode parameters
  • Scent Mode parameters
  • Trigger Mode parameters
  • Screen brightness
  • Language
  • Buzzer
  • Version information
  • Reset

18. SCREEN BRIGHTNESS

Screen brightness can be adjusted according to the surrounding environment.

Use the brightness control in the Settings interface to select the desired display level.

19. LANGUAGE

The system interface supports:

  • Chinese
  • English

The original documentation notes that the mainland-China sales version temporarily does not support switching the interface to English.

20. BUZZER

The built-in buzzer can be enabled or disabled.

When enabled, the system provides audible valve-status indications:

  • One beep during ventilation
  • Two beeps during closure

This provides an audible indication of valve-state changes during operation.

21. VERSION INFORMATION

The Settings interface provides system version information.

The version-information section can be used to identify the current software/system version installed on the main unit.

22. RESET

The system provides a dedicated Reset function.

Reset can be used to clear stored mode parameters.

IMPORTANT

Use Reset only when you intend to clear the stored settings.

23. PARAMETER STORAGE

The system supports parameter storage.

Depending on the operating mode, configured parameters can be retained after power-off.

The Save function is provided for storing configured operating parameters.

Reset can be used to clear stored parameters.

24. BASIC OPERATING STRUCTURE

The overall system workflow is:

POWER ON

SYSTEM SELF-TEST

HOME SCREEN

SELECT OPERATING MODE

CONFIGURE PARAMETERS

START OPERATION

MONITOR REAL-TIME STATUS

STOP / AUTOMATIC STOP / EMERGENCY STOP

The available parameters and controls depend on the selected operating mode.

25. SAFETY INFORMATION

25.1 EMERGENCY STOP

Always keep the emergency-stop switch immediately accessible.

In an emergency, activate the emergency-stop switch immediately.

25.2 IMMEDIATE MANUAL CONTROL

The system should only be operated when an authorized user is able to intervene immediately.

Do not operate the system in circumstances where the emergency-stop control cannot be accessed.

25.3 TRIGGER ELECTRICAL SAFETY

The Trigger Mode input is designed for passive switching signals.

Never apply external voltage to the Trigger Mode input.

Incorrect electrical connections may damage the main unit.

25.4 CONTINUOUS OPERATION

Loop Mode and Random Mode can operate continuously when Infinite Loop is enabled.

Always maintain immediate access to the manual stop and emergency-stop controls.

25.5 EQUIPMENT INSPECTION

Before operation, inspect:

  • Main unit
  • Air-tube connections
  • Cables
  • Connectors
  • Remote controller
  • Connected accessories

Do not use damaged equipment.

25.6 MODIFICATIONS

Do not modify the main unit, electrical circuitry, valve system, or safety-related functions without authorization from DESPAIR-LAB.

Only use compatible accessories and connections.

26. TECHNICAL SPECIFICATIONS

SpecificationDetailsProductBREATH CONTROL SYSTEM 1.0BrandDESPAIR-LABDisplay2.8-inch touchscreenPower / Emergency Stop Switch16 mmAir-Tube ConnectionStandard 40 mmMain-Unit Charging Interface12.6VSupplied Charger12.6VScent Signal Interface3.5 mmTrigger Signal Interface2.5 mmRemote ControllerIncludedTrigger Connection Cable2.5 mm connectorOperating ModesLoop / Random / Scent / TriggerMinimum Ventilation Time6 secondsMaximum Closure Time60 secondsScreen BrightnessAdjustableLanguageChinese / EnglishBuzzerOn / OffVersion InformationAvailableParameter StorageSupportedParameter ResetSupported

27. QUICK REFERENCE

LOOP MODE

Configurable:

  • Valve Synchronization
  • Infinite Loop
  • Ventilation Time
  • Closure Time
  • Cycle Count
  • B Valve
  • Save

RANDOM MODE

Configurable:

  • Valve Synchronization
  • Ventilation Time Range
  • Closure Time Range
  • B Valve
  • Continuous Operation

SCENT MODE

Configurable:

  • Infinite Loop
  • Ventilation Time
  • Scent Delivery Time
  • Closure Time
  • Cycle Count
  • Save

Requires a compatible scent-control unit.

REMOTE CONTROL

Provides:

  • One-key remote activation
  • A Valve control
  • B Valve control
  • Touchscreen manual control

TRIGGER MODE

Provides:

  • External passive-switch triggering
  • 2.5 mm trigger interface
  • Compatibility with suitable external switching/sensing equipment

External voltage input is prohibited.

28. IMPORTANT SAFETY REMINDER

BREATH CONTROL SYSTEM 1.0 is a control device, not a medical device.

The timing ranges provided by the system represent available device parameters and should not be interpreted as recommended operating durations.

Always maintain immediate access to the emergency-stop control and ensure that the system can be stopped immediately.

Never use damaged equipment, blocked air passages, incompatible accessories, or unauthorized electrical connections.

If any abnormal condition, discomfort, malfunction, or unexpected system behavior occurs, stop operation immediately and disconnect the system from use.

29. SUPPORT

For product compatibility, technical support, accessory compatibility, or system-related questions, please contact DESPAIR-LAB through the official customer-support channel.

When contacting support, provide:

  • Product name
  • System version
  • Description of the issue
  • Connected accessory information
  • Relevant photographs or videos when applicable

DESPAIR-LAB

BREATH CONTROL SYSTEM 1.0

ENGINEERED FOR CONTROL